Skip to main content
NEXA Logo

Multi Loose Tube Cable SRP

Universal multi-loose-tube cable with standard rodent protection, up to 432 fibres in 36 loose tubes

  • Up to 432 fibres in 36 loose tubes
  • Water-blocking E-glass yarn (WBF)
  • FRP dielectric central strength member
  • Standard rodent protection
  • Construction codes: JB12 (FRNC) / JB1K (HDPE)
Multi Loose Tube Cable SRP

Fibre count

48 – 432

Cable Ø

9.1 – 22.6 mm

Rodent protection

SRP

Jacket

FRNC / HDPE / PE

Application

Universal

Gallery

  • Multi Loose Tube Cable SRP — 1

Available Variants

Max. fibresCable Ø (mm)Weight FRNC/HDPE (kg/km)Tensile (N)
489.187 / 661000
7210.5117 / 922400
9611.8144 / 1173400
14414.6210 / 1744800
21617.8269 / 2192400
43222.6426 / 3702400

Technical Specifications

  • Construction code

    JB12 / JB1K

  • Standard put-up length

    2100 / 4100 m

  • Impact resistance

    3 (w/20Nm)

  • Min. bending radius

    15 × D

  • Outer jacket

    FRNC / HDPE / PE

  • Temperature (operation)

    -40 °C to +70 °C

  • Lifetime

    30 years

Key Features

  • Standard rodent protection

    Water-blocking E-glass yarn provides SRP.

  • Up to 432 fibres

    Highest fibre count in this product family.

  • Gel-filled loose tubes

    Up to 36 loose tubes.

  • FRP central strength member

    Dielectric, non-metallic.

Available Variants

  • SRP
  • Up to 432F
  • FRNC / HDPE

Request Technical Information

Get detailed technical specifications, installation guides and product documentation for your project planning.

Read